37 lines
948 B
Plaintext
37 lines
948 B
Plaintext
[fan]
|
|
# When the temperature is above lv0 (35'C), the fan at 25% power,
|
|
# and lv1 at 50% power, lv2 at 75% power, lv3 at 100% power.
|
|
# When the temperature is below lv0, the fan is turned off.
|
|
# You can change these values if necessary.
|
|
lv0 = 35
|
|
lv1 = 40
|
|
lv2 = 45
|
|
lv3 = 50
|
|
|
|
[key]
|
|
# You can customize the function of the key, currently available functions are
|
|
# slider: oled display next page
|
|
# switch: fan turn on/off switch
|
|
# reboot, poweroff
|
|
# If you have any good suggestions for key functions,
|
|
# please add an issue on https://github.com/radxa/rockpi-penta/issues
|
|
click = slider
|
|
twice = switch
|
|
press = none
|
|
|
|
[time]
|
|
# twice: maximum time between double clicking (seconds)
|
|
# press: long press time (seconds)
|
|
twice = 0.7
|
|
press = 1.8
|
|
|
|
[slider]
|
|
# Whether the oled auto display next page and the time interval (seconds)
|
|
auto = true
|
|
time = 10
|
|
|
|
[oled]
|
|
# Whether rotate the text of oled 180 degrees, whether use Fahrenheit
|
|
rotate = false
|
|
f-temp = false
|